Hauptseite > Publikationsdatenbank > A new method to find out the optimal neutron moderator size based on neutron scattering instrument parameters |
Journal Article | FZJ-2024-02440 |
;
2023
North-Holland Publ. Co.
Amsterdam
This record in other databases:
Please use a persistent id in citations: doi:10.1016/j.nima.2023.168643 doi:10.34734/FZJ-2024-02440
Abstract: Simple and fast analytic method to find optimal combinations of sizes of neutron moderator and optical system entrance, allowing for the full sample illumination with minimum to none background, is developed. In the case of employing low-dimensional para-hydrogen moderators with enhanced neutron beam brilliance, the method allows to determine the minimum size of moderator, which provides the highest sample flux while keeping the sample fully illuminated.This method can be used during the design of new neutron sources, upgrades of neutron optical systems and moderator replacements.
Keyword(s): Basic research (1st) ; Instrument and Method Development (2nd)
![]() |
The record appears in these collections: |