Journal Article PreJuSER-13462

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Measurements of biogenic VOC emissions : sampling, analysis and calibration

 ;  ;  ;

2001
Elsevier Science Amsterdam [u.a.]

Atmospheric environment 35, 2069 - 2080 () [10.1016/S1352-2310(00)00502-1]

This record in other databases:  

Please use a persistent id in citations: doi:

Abstract: We describe an experimental sq stem and techniques for sampling and analyzing biogenic emissions of volatile organic compounds (VOC). The system uses a Teflon chamber to enclose a single branch of a tree. Temperature, photosynthetic active radiation (PAR), relative humidity and carbon dioxide concentration are continuously monitored with a time resolution of five minutes. VOCs are sampled on tubes containing solid adsorbents (Tenax TA and Carbotrap) with a time resolution of 1 h. Composition and concentration of VOC emissions are measured with a gas chromatographic system equipped with a flame ionization detector (FID) for quantitative and a mass spectrometer (MS) for qualitative analysis. To calibrate the system, a diffusion source was built to produce standard mixtures of up to 36 different compounds with mixing ratios at low concentrations and high accuracy. The diffusion rates were monitored over 17 months and shelved variations between 0.2 and 7.6% for monoterpenes (expect for alpha -phellandrene, alpha -terpinene and gamma -terpinene) and between 10.6 and 22.6% for sesquiterpenes. FID response factors calculated from calibration measurements were corrected using correction factors based on the effective carbon number concept. The individual response factors of 23 compounds were combined to a mean response factor (RFm) with a value of 23,100 muV s ng(-1) and a standard deviation of 9%. The system described here was used to measure VOC emission rates of Scots pine (Pinus sylvestris) in 1998 and 1999. (C) 2001 Elsevier Science Ltd. All rights reserved.

Keyword(s): J ; monoterpenes (auto) ; enclosure chamber (auto) ; diffusion device (auto)


Note: Record converted from VDB: 12.11.2012

Contributing Institute(s):
  1. Troposphäre (ICG-II)
Research Program(s):
  1. Troposphärische Chemie (36.30.0)

Appears in the scientific report 2001
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > ICE > ICE-3
Workflow collections > Public records
IEK > IEK-8
Publications database

 Record created 2012-11-13, last modified 2024-07-09



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)