Journal Article PreJuSER-29559

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Track structures and dose distributions from decays of I-131 and I-125 in and around water spheres simulating micrometastases of differentiated thyroid cancer

 ;  ;  ;  ;  ;  ;

2001
Radiation Research Society Great Falls, Va.

Radiation research 156, 419 - 429 () [10.1667/0033-7587(2001)156[0419:TSADDF]2.0.CO;2]

This record in other databases:  

Please use a persistent id in citations: doi:

Abstract: The disintegration of the radionuclides I-131 and I-125 and the subsequent charged-particle tracks left behind in water (as a model substance for a biological cell) are simulated by the Monte Carlo track structure simulation code PARTRAC, using new inelastic electron scattering cross sections for condensed water. Every photon and electron emitted was followed in detail, event by event, down to 10 eV. From the spatial information on the track structures, absorbed dose distributions per I-131 and I-121 decay were calculated in and around water spheres simulating micrometastases as well as in the tissue surrounding such metastases. These radionuclides were assumed to be distributed uniformly inside spheres of different diameters (0.01, 0.03, 0.1, 0.3, 1.0 and 3.0 nun). The respective electron degradation spectra, the nearest-neighbor distance distributions between inelastic events, and the distance distributions for all activations for both iodine radionuclides were calculated. The absorbed fractions of the initial electron energies, absorbed doses and energy depositions, and single-event distributions, F-1(epsilon), inside the six water spheres described above and in the surrounding tissue were also calculated. The absorbed doses per decay inside the six water spheres, i.e., the calculated S values (listed from 0.01 to 3.0 nun), were 6.8 x 10(-4), 7.2 x 10(-5), 5.5 x 10(-6), 4.9 x 10(-7), 3.1 x 10(-8) and 1.8 x 10(-9) Gy Bq(-1) s(-1) for I-131, and 3.4 x 10(-3), 1.7 x 10(-4), 5.1 x 10(-6), 2.0 x 10(-1), 5.6 x 10(-9) and 2.2 x 10(-11) Gy Bq(-1) s(-1) for I-125. It is concluded that in the treatment of thyroid cancer, the geometrical track structure properties of I-125 might be superior to those of I-131 in micrometastases with diameters less than 0.1 nun; however, in this medical context, many other factors also have to be considered. (C) 2001 by Radiation Research Society.

Keyword(s): J


Note: Record converted from VDB: 12.11.2012

Contributing Institute(s):
  1. Abteilung Sicherheit und Strahlenschutz (ASS)
Research Program(s):
  1. Begleitende Arbeiten zur Umgebungsüberwachung (51.10.1)

Appears in the scientific report 2001
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Workflow collections > Public records
Publications database

 Record created 2012-11-13, last modified 2017-06-01



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)