Abstract: Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used.The simulation has shown that all PMT designs with no homogeneous axial coverage obviously have a very nonlinear corresponding axial sensitivity profile. By shifting every other detector module by a quarter of a PMT length in axial direction the sampling of the FOVs became more homogeneous. Applying an energy threshold of 350 keV, the regression coefficient increases from 0.818 for the nonshifted to 0.993 for the shifted design. Simulating a point source centered in the FOV (threshold: 350 keV) resulted in sensitivities of 4.2% for a 4 x 20PMT (LSO/LuYAP a 10 mm) and 3.8% for a 4 x 16PMT (LSO/LuYAP A 8 mm) ring design. The 3-D MLEM reconstruction of a point source shows the enormous improvement of resolution using a crystal double layer with DOI [3.1 mm at 40 mm from center FOV (CFOV)] instead of a 20 mm single layer (7.1 mm).

Keyword(s): J ; axial shift (auto) ; ClearPET (auto) ; depth of interaction(DOI) (auto) ; GEANT3 (auto) ; LSO/LuYAP phoswich (auto) ; simulation (auto) ; small animal positron emission tomography (PET) (auto)


Note: Record converted from VDB: 12.11.2012

Contributing Institute(s):
  1. Institut für Medizin (IME)
  2. Zentralinstitut für Elektronik (ZEL)
Research Program(s):
  1. Neurowissenschaften (L01)

Appears in the scientific report 2003
Notes: This version is available at the following Publisher URL: http://ieeexplore.ieee.org/Xplore/dynhome.jsp
Database coverage:
OpenAccess
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > ZEA > ZEA-2
Institute Collections > PGI > PGI-4
Workflow collections > Public records
Publications database
Open Access
INB-3

 Record created 2012-11-13, last modified 2025-01-29


OpenAccess:
Download fulltext PDF
External link:
Download fulltextFulltext by OpenAccess repository
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)