Abstract: The in-situ performance of heat flux plates within coarse porous substrates might be limited due to poor contact between plate and substrate. We tested this behaviour with a simple laboratory set-up. Two test substrates were placed above a reference material of known thermal conductivity between a warm and a cold plate to establish a vertical heat flux. The temperature gradients and the response of a soil heat flux plate were measured. By means of the Fourier law of heat conduction the thermal conductivity of each test substrate was calculated, thus incorporating all heat transfer within the volume and representing the "effective" conductivity. The laboratory method had an accuracy of up to 7% (13% for a smaller set-up). In comparison, heat flux plate-derived heat fluxes showed errors of up to 26%. Use of heat flux plates in coarse substrates is not recommended without additional measurements.

Keyword(s): J


Note: Record converted from VDB: 12.11.2012

Research Program(s):
  1. Terrestrische Umwelt (P24)

Appears in the scientific report 2007
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > IBG > IBG-3
Workflow collections > Public records
Publications database

 Record created 2012-11-13, last modified 2018-02-11



Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)