Implementation of an Enclosed Ionization Interface for the Analysis of Liquid Sample Streams with Direct Analysis in Real Time Mass Spectrometry

 ;  ;  ;

2021
Wiley Interscience New York, NY

Rapid communications in mass spectrometry 35(13), e9091 () [10.1002/rcm.9091]

This record in other databases:      

Please use a persistent id in citations:   doi:

Abstract: Rationale: The development of an interface to introduce liquid sample streams to directanalysis in real time mass spectrometry (DART-MS) is of great interest for coupling variousanalytical techniques, using non-volatile salts, with MS. Therefore, we devised an enclosedionization interface and a sample introduction system for the versatile analysis of liquidsamples with DART-MS.Methods: The sample introduction system consists of a nebulizer, a spray chamber and atransfer line, while the confined ionization interface is created by implementing a cross-shapedhousing between the ion source and the MS inlet. Methodical studies of the effects of varioussetup parameters on signal intensity and peak shape were conducted, while its diverseapplicability was demonstrated by coupling with high-performance liquid chromatography(HPLC) for the analysis of alcohols, organic acids and furanic compounds.Results: The confinement of the ionization interface results in a robust setup design with awell-defined ionization region for focusing of the sprayed sample mist. Thereby, an increasein analyte signal intensity by three orders of magnitude and improved signal stability andreproducibility were obtained in comparison to a similar open ionization interfaceconfiguration. Additionally, the successful quantification of alcohols could be demonstrated aswell as the compatibility of the setup with HPLC gradient elution.Conclusions: A versatile setup design for the analysis of liquid sample streams with DARTMSwas devised for monitoring reactions or hyphenating analytics with MS. It minimizesThis article is protected by copyright. All rights reserved.interferences from the laboratory surrounding as well as allows for safe handling of hazardousand toxic chemicals, which renders it suitable for a broad range of applications.

Classification:

Contributing Institute(s):
  1. Helmholtz-Institut Erlangen-Nürnberg Erneuerbare Energien (IEK-11)
Research Program(s):
  1. 123 - Chemische Energieträger (POF4-123) (POF4-123)

Appears in the scientific report 2021
Database coverage:
Medline ; Creative Commons Attribution-NonCommercial CC BY-NC 4.0 ; OpenAccess ; BIOSIS Previews ; Biological Abstracts ; Clarivate Analytics Master Journal List ; Current Contents - Physical, Chemical and Earth Sciences ; DEAL Wiley ; Ebsco Academic Search ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Dokumenttypen > Aufsätze > Zeitschriftenaufsätze
Institutssammlungen > IET > IET-2
Workflowsammlungen > Öffentliche Einträge
Workflowsammlungen > Publikationsgebühren
IEK > IEK-11
Publikationsdatenbank
Open Access

 Datensatz erzeugt am 2021-05-17, letzte Änderung am 2024-07-12


OpenAccess:
Volltext herunterladen PDF
Externer link:
Volltext herunterladenFulltext by OpenAccess repository
Dieses Dokument bewerten:

Rate this document:
1
2
3
 
(Bisher nicht rezensiert)