Journal Article FZJ-2019-03173

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Sub‐millimeter T 1 mapping of rapidly relaxing compartments with gradient delay corrected spiral TAPIR and compressed sensing at 3T

 ;  ;

2019
Wiley-Liss New York, NY [u.a.]

Magnetic resonance in medicine 82(4), 1288-1300 () [10.1002/mrm.27797]

This record in other databases:      

Please use a persistent id in citations: doi:

Abstract: PurposeThe TAPIR sequence is an accurate and efficient method for T1 mapping. It combines a slice‐interleaving Look‐Locker read‐out with an acquisition of multiple k‐space lines in 1 shot. Whereas the acquisition of multiple lines per excitation increases imaging speed, the corresponding increase in TR and TE is detrimental to the T1 fitting performance. This is especially problematic for substances exhibiting rapid T2* relaxation (e.g., myelin water).MethodsThe T1 fitting performance of TAPIR is enhanced by using an interleaved spiral read‐out with shorter TE and TR. Furthermore, an improvement to a method for fast gradient delay estimation is presented. Whereas previous methods assume the gradient delay to be stationary, the presented approach corrects the spiral k‐space trajectory by using a polynomial fit of the measured gradient delays.ResultsGradient delay artifacts are largely eliminated, requiring very little additional scanning time. The sampling efficiency of the spiral read‐out allows for a significant reduction of the acquisition time in comparison to Cartesian TAPIR. Spiral TAPIR enables the sampling of more slices and an accurate measurement of rapidly relaxing compartments. Over a wide T1 range (448–3115 ms), spiral TAPIR reduces the mean fitting error from −2.5% to −0.1%. Combining 50% undersampling with the shorter TR of spiral TAPIR, an increase in imaging speed by a factor of up to 3.3 was achieved.ConclusionUsing a spiral read‐out trajectory, the established TAPIR sequence enables measurement of rapidly relaxing T1 compartments, while improving T1 mapping performance and imaging speed.

Classification:

Contributing Institute(s):
  1. Physik der Medizinischen Bildgebung (INM-4)
  2. Jara-Institut Quantum Information (INM-11)
  3. JARA-BRAIN (JARA-BRAIN)
Research Program(s):
  1. 573 - Neuroimaging (POF3-573) (POF3-573)

Appears in the scientific report 2019
Database coverage:
Medline ; BIOSIS Previews ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Current Contents - Life Sciences ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
JARA > JARA > JARA-JARA\-BRAIN
Institute Collections > INM > INM-11
Institute Collections > INM > INM-4
Workflow collections > Public records
Publications database

 Record created 2019-06-04, last modified 2021-01-30


Restricted:
Download fulltext PDF Download fulltext PDF (PDFA)
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)